Electrical parameters
| Parameter | Sign | Minimum | Typical | Maximum | Unit | Notes |
| power-on reset | VDDPOR | 2.8 | V | |||
| Working current | Iavdd | 2.0 | 3 | mA | Working mode | |
| 200 | nA | Standby current | ||||
| ADC resolution | RESRAW | 24 | Bits | |||
| Output pressure accuracy 1,2 | ACC | 1% | %FS | 0°C ~ 60°C | ||
| 1.5% | %FS | -20°C ~ 70°C | ||||
| Power on time | TUP | 100 | ms | adjustable | ||
| EEPROM data hold | Tlive | 10 | years | @125℃ |
1. Accuracy includes nonlinearity, temperature hysteresis, and pressure hysteresis;
2. Full life accuracy based on 1000 hours of HTOL, LTOL, HTSL, THB, and PCT testing;
I2C Electrical characteristics
| Parameter | Sign | Minimum | Maximum | Unit | Notes |
| Clock frequency | fBsclB | 1 | MHz | R=1K | |
| Clock low pulse maintenance time | tBLOWB | 0.52 | us | ||
| Clock high pulse maintenance time | tBHIGHB | 0.24 | us | ||
| SDA establishment time | tBSUDATB | 0.1 | us | ||
| SDA holding time | tBHDDATB | 0.0 | us | ||
| Establishment time at the beginning of each session | tBSUSTAB | 0.24 | us | ||
| Starting condition maintenance time | tBHDSTAB | 0.24 | us | ||
| Stop time, Establish time | tBSUSTOB | 0.24 | us | ||
| The interval time between two communications | tBBUFB | 0.52 | us |